第七章 骨科植入材料Orthopedic Implants

        外傷和疾病的末期如骨關節炎(osteoarthritis)和風濕性關節炎(rheumatoid arthritis)會造成肌肉骨骼系統(musculoskeletal system)的損傷,這些過程會造成傷害性的移動和高度疼痛,因此需以外科來治療。組織移植和合成的高分子材料備用來治療損傷的機件和韌帶,而關節置換主要是金屬和高分子材料,固定元件包括骨板和螺絲用來強化骨頭破裂,這些裝置由金屬製成,高分子材料尚在實驗性地研究階段

7.1. 線、軸釘和螺絲 (wires, pins, and screws)

7.2. 骨板

7.3. 骨髓內裝置

7.4. 關節置換

 

參考文獻

[1]         F. H. Silver, “Biomaterials, medical devices and tissue engineering: an integrated approach,” Chapman & Hall, London, UK, 1994, p. 92.

[2]         J. B. Park and R. S. Lakes, “Biomaterials: an introduction,” 2nd ed., Plenum Press, New York, 1992, p. 293.

[3]         B. K. F. Kummer, “Biomechanics of bone,” in Biomechanics: its foundations and objectives,” Y. C. Fung, N. Perrone, and M. Anliker (eds.), Prentice-Hall, Engle-wood Cliffs, N.J., 1972, p. 263.

[4]         D. C. Mears, “Materials and orthopedic surgy,” Williams and Wilkins, Baltimore, 1979.

[5]         Smith & Nephew Richards, Inc., Bone Screw Technical Information, Technical Publ. No. 4167, Memphis, Tenn., 1980.

[6]         J. A. Albright, T. R. Johnson, and S. Saha, “Principles of internal fixation,” in Orthopedic mechanics: Procedures and Devices, D. N. Ghista and R. Roaf (eds.), Academic Press, New York, 1978, pp. 123-199.

[7]         M. Laurance, M. A. R. Freeman, and S. A. V. Swanson, “Engineering considerations in the internal fixation of fractures of the tibial shaft,” J. Bone joint Surg., 51B, 754-768, 1969.

[8]         M. Allgower, P. Matter, S. M. Perren, and T. Ruedi, “The dynamic compression plate, DCP,” Springer-Verlag, Berlin, 1973, p. 18.

[9]         A. Brown and J. C. D’Arcy, “Internal fixation for supra-condylar fractures of the femur in elderly patients,” J. Bone Joint Surg., 53B, 420-424, 1971.

[10]     H. M. Frost, “Orthopedic biomechanics,” Charles C. Thomas Publ., Springfield, III., 1973, p. 444.

[11]     J. P. Paul, “Loading on normal hip and knee joints and joint replacements,” in Advances in hip and knee joint technology, M. Schaldach and D. Hohmann (eds.), Springer-Verlag, Berlin, 1976, pp. 53-70.

[12]     J. L. Lewis and W. D. Lew, “Bioengineering of total joint replacement,” in Handbook of bioengineering, R. Skalak and S. Chien (eds.), McGraw-Hill Book Co., NY, Ch. 40.

[13]     J. Charnley, “A biomechanical analysis of the use of cement to anchor the femoral head prosthesis,” J. Bone Jt. Surg., 47B, 354, 1965.

[14]     Biomedical business international, vol. 13, No. 3, March 23, 1990.

[15]     S. A. V. Swanson and M. A. R. Freeman (eds.), “The scientific basis of joint replacement,” J. Wiley and Sons, NY, 1977.

[16]     J. T. Scales, “Loosening of the total hip replacements with cement fixation,” Clin. Orthop. Relat. Res., 72, 145-160, 1970.

[17]     A. S. Greenwald and M. B. Matejczyk, “Knee joint mechanics and implant evaluation,” in Total knee replacement, A. A. Savastano (ed.), Appleton-Century-Crofts, NY, 1980, p. 1130.

[18]     L. Marmor, in Total knee replacement, A. A. Savastano (ed.), Appleton-Century-Crofts, NY, 1980, pp. 107-123.

[19]     M. A. R. Freeman, in Total knee replacement, A. A. Savastano (ed.), Appleton-Century-Crofts, NY, 1980, pp. 59-82.

[20]     D. A. Sonstegard et al., J. Bone Joint Surg., 59A, 602-616, 1978.

[21]     B. Walldius, in Total knee replacement, A. A. Savastano (ed.), Appleton-Century-Crofts, NY, 1980, pp. 195-216.

[22]     C. O. Bechtol, “Bechtol patello-femoral joint replacement system,” Smith & Nephew, Inc., Memphis, Tenn.

[23]     N. J. Rutherford, “The porous coated anatomic (PCA) total knee system,” Orthopaedic Division, Howmedica, Inc., 1981.

[24]     S. K. Yen, M. J. Guo, and H. Z. Zan, “Characterization of electrolytic ZrO2 coating on Co-Cr-Mo implant alloys of hip prosthesis,” Biomaterials, in press.

[25]     S. K. Yen and S. W. Hsu, “Electrolytic Al2O3 coating on Co-Cr-Mo implant alloys of hip prosthesis,” J. Biomed. Mater. Res., in press.

[26]     G. H. Harth, “Metal implants for orthopedic and dental surgery,” Metals and Ceramics Information Center, MCIC Report, Battelle Columbus Labs, Columbus, Ohio.

[27]     L. Smith, “Ceramic-plastic material as a bone substitute,” Arch. Surg. (Chicago), 87, 653.

[28]     P. Predecki, “Attachment of bone to thread implants by ingrowth and mechanical inter-locking,” J. Biomed. Mater. Res., 6, 401-412, 1972.

[29]     J. Galante, W. Rostoker, R. Lueck, and R. D. Ray, “Sintered fiber metal composites as a basis for attachment of implants to bone,” J. Bone Jt. Surg., Am. Vol. 53A, 101-114, 1971.

[30]     J. S. Hirschhorn, A. A. McBeath, and M. R. Dustoor, “Porous titanium surgical implant materials,” Biomed. Mater. Symp., 2, 49-67, 1972.

[31]     R. P. Welsh, R. M. Pilliar, and I. MacNab, “Surgical implants-Role of surface porosity in fixation to bone and acrylic,” J. Bone Jt. Surg., Am. Vol. 53A, 963-977, 1971.

[32]     C W. Cao and L. L. Hench, “Bioactive materials,” Ceramics International, 22, 493-507, 1996.

[33]     林奇民, “電解沈積Al2O3-HA生醫陶瓷於純鈦金屬上之研究,” 中興大學碩士論文, 2000.  

       相關網站: 

1.  The total hip replacement

2. The total shoulder replacement

3. The total knee replacement 

4. 華人骨科專業資訊網

5.中華民國生物醫學工程學會首頁

6.Society For Biomaterials

7. 台北榮民總醫院

                   

回上一頁